Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


133 LPI at 1200 dpi is not available in Prinergy 2.0.7.19 and later


Product

  Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 


Symptoms

 

I used to be able to select 133 LPI at 1200 DPI. After upgrading past Prinergy 2.0.7.19, I cannot do so.


Cause

 

Solution

 

There are visual problems with 133 LPI at 1200 DPI, since mathematically it cannot really be done cleanly.

Because there were problems noticed with this combination (133 LPI at 1200 DPI), Prinergy removed that possiblity from Workshop.

The next nearest LPIs that work at 1200 DPI are 120 or 141 LPI.

Permanent fix:


See also

 


Keywords

 

screening


Technical contact(s)
 

James Bredenhof

Submitted by
 

James Bredenhof

Date submitted
 

21 Nov 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.