Error |
||
|
|
||
Symptoms |
When one or more objects are selected in Dotshop and screens or calibration curves are assigned, other, non-selected objects may also be rendered with different screens or calibration curves other than those screens/curves selected in the process plan.
|
|
|
|
||
Cause |
Due to a limitation in Adobe Acrobat 5.0, the tags that are identifying the screens or curves may be attached to multiple objects at the same time. This will happen more frequently with complex files and grouped objects. | |
|
|
||
Solution |
This problem is solved in the new version of Dotshop, delivered with Prinergy 2.2.1.5 and later. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
acrobat, Dotshop |
|
|
|
||
Technical contact(s) |
Dirk De keersmaecker |
|
Submitted by |
Dirk De keersmaecker |
|