Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


File fails in Normalizer with limitcheck on clip or eoclip


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

File inexplicably fails in the Normalizer with a limitcheck on clip or eoclip.


Cause

  Bug in Normalizer.

Solution

 

Set the Normalizer to 300 dpi and the file should work.

In the registry, ...\Default\ENOR\JTPName\MaxXResolution and MaxYResolution.

NOTE: It is not a good idea to permanently keep the Normalizer at 300 dpi as there or some instances where this causes problems.

Note that later versions of Prinergy have more recent versions of Normalizer, and might already correct this (2.1 = Normalizer 5, 2.3 = Normalizer 6).

As an alternate workaround, you might have success Distilling in a recent Distiller prior to bringing into Prinergy.

Permanent fix:


See also

 


Keywords

 

normalizer, RIP


Technical contact(s)
 

James Bredenhof

Submitted by
 

James Bredenhof

Date submitted
 

14 Jan 2004