Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Output fails when device path is set to %JOB%


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 ; Prinergy Satellite

Platform

 

Operating system

 


Error

 

21Aug02 12:39:41.203-PDT [2984.3892] HOBGOBLIN AraxiLab PTaskD.XCON_Callback TAKS_JobSub.cpp(1354): HiRes(512):printing: Failed renaming temporary output file. Operating system reported The process cannot access the file because it is being used by another process.


Symptoms

 

Loose page or imposed output fails when device path is set to %JOB% in process plan.


Cause

 

Solution

 

When the output destination is set to job relative, ensure that it is to a subfolder of %Job%. i.e. %Job%\Proofs

Permanent fix:


See also

 


Keywords

 

output, proofing


Technical contact(s)
 

Simon Chen

Submitted by
 

Simon Chen

Date submitted
 

11 Nov 2002