Duotone data (Black+Spot) appear as negative images on an EPSON 9000


Product

  Prinergy 1.1

Platform

 

Operating system

 


Error

 


Symptoms

 

NOTE: This problem is related to the Postscript 3 output feature ONLY. When PostScript output is generated for a page containing duotone eps images (spot color plus black), they appear as inverted black images (like a monochrome negative), when printed on an Epson9000 via the Fiery RIP.

To reproduce:

Create a LoosePage process plan to generate PostScript 3 output. Use this PP to generate a Postscript 3 file for a page containing duotone (black+spot) data. Send the created PostScript file to the EPSON 9000 via the Fiery RIP. Observe that the duotone data containing the spot colors appear as negative black/white images.


Cause

 

Solution

 

Edit the Epson9000Header.PS file (this file can be found in the %ARAXIHOME%\AdobeExtreme\bin directory). Add the following two lines after the line containing the /ProcessColorModel key:

dup /SeparationColorNames undef

dup /SeparationOrder undef

Save the file. Restart ProofWorks and do the same test. This time you should observe the duotone images displayed correctly.