Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Harmony database information does not appear when opening up PPED


Product

  Prinergy 1.0

Platform

 

Operating system

 


Error

 


Symptoms

 

Harmony database information does not appear when opening up the PPED.


Cause

  There are two possible causes:

1) The Harmony database is not loaded.

2) Print Console is not started.


Solution

 

1) The Harmony database is not loaded:

Check the Registry key HKLM\Software\Creo\Araxi\...\SCRN\HarmonyDatabaseFile and HarmonyDatabaseShare. Make sure these point to the database file and share on the primary server where the Harmony database resides.

2) Print Console is not started:

If it's a final output JTP, it is possible that the device type info has not been sent yet because Print Console hasn't been started.

Start Print Console.

Permanent fix:


See also

 


Keywords

 

Harmony, pped


Technical contact(s)
 

Simon Chen

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.