Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 1.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
If you check the box to enable gutter reducing and then set the min gutter to zero, when you next open the process plan, the check box is no longer checked. |
|
|
|
||
Cause |
If you set preferred gutters to zero, you cannot expect any more reduction, so the reduce box is automatically unchecked. | |
|
|
||
Solution |
No workaround needed. As stated above, if you set preferred gutters to zero, no more reduction is possible. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
workshop |
|
|
|
||
Technical contact(s) |
Gordon Miller |
|
Submitted by |
||
Date submitted |
||