When processing CT/LW, Prinergy CEPS JTP creates a PDF page with a 0,0 LW offset


Product

  Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Satellite

Platform

 

Server: Dell all; Client: PC or Macintosh

Operating system

 

Server: Windows 2000; Client: Windows or Macintosh


Error

 


Symptoms

 

CEPS JTP will create a PDF page with a 0,0 LW offset from a CT/LW page with a non-zero LW offset.


Cause

  A CT/LW page has an assign file that specifies the locations of the various components. Normally, the offset location of the LW file is 0,0. If the file's offset has been altered or if an application changes the offset location to something other than 0,0, the CEPS JTP ignores the change. LW offset in final PDF will always be 0,0, regardless of the offset in the assign file.

Note: the Brisque does not create LW with offsets other than 0,0.


Solution

 

Use a third party application such as CEPSLink to create DCS files from the pages and then process in Prinergy.

Permanent fix:


See also

 


Keywords

 

CT-LW Import, Geometry