Prinergy CEPS and CEPSLink JTPs fail when processing separated CT/LW files


Product

  Prinergy Connect 2.0

Platform

 

Server: Dell all; Client: PC or Macintosh

Operating system

 

Server: Windows 2000; Client: Windows or Macintosh


Error

 


Symptoms

 

***Applies to Prinergy Connect, Powerpack, Direct, Satellite, depending on installed configuration.***

Separated CT/LW file submitted to the CEPS JTP fails. Separated CT/LW file submitted to CEPSLink also fails.


Cause

  A CT/LW file will be separated when printing separated PS and submiting the file to the Brisque.

There is also an extreme case which is less likely: if your LW is excessively complex and exceeds 64,000 colors, the Brisque will automatically separate the CT/LW.


Solution

 

A. If the CT/LW is separated because of separated PS input, then you can re-composite the CT/LW on the Brisque using the Merge function.

This will result in composite CT/LW that will process with either the CEPS JTP or CEPSLink.

B. If the input PS is composite, and the Merge function doesn't work due to the complexity of the LW, re-RIP the PS with different Brisque settings. For example, render vignettes to CT.