Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


OPI fails with error: "Image reader Scitex CT failed to read the file <... .EPS>"


Product

  Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 


Symptoms

 

OPI fails and reports error message: "Image reader Scitex CT failed to read the file <... .EPS>"


Cause

  This message is probably caused by a user attempting to recompose a DCS when performing OPI into composite PS, when the DCS has more than 8 channels. Prinergy can currently handle only 8 channels in this manner.

Solution

 

There are two possible solutions:

1. Reduce the number of separations in the DCS by removing unnecessary channels in Photoshop.

2. Alternately, if the job requires 8 separations for the image, you can output separated PS or build the file with overprinting images.

Permanent fix:


See also

 


Keywords

 

normalizer, OPI, Photoshop


Technical contact(s)
 

James Bredenhof

Submitted by
 

James Bredenhof

Date submitted
 

30 May 2003


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.