Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
OPI fails and reports error message: "Image reader Scitex CT failed to read the file <... .EPS>" |
|
|
|
||
Cause |
This message is probably caused by a user attempting to recompose a DCS when performing OPI into composite PS, when the DCS has more than 8 channels. Prinergy can currently handle only 8 channels in this manner. | |
|
|
||
Solution |
There are two possible solutions: 1. Reduce the number of separations in the DCS by removing unnecessary channels in Photoshop. 2. Alternately, if the job requires 8 separations for the image, you can output separated PS or build the file with overprinting images. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
normalizer, OPI, Photoshop |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
James Bredenhof |
|
Date submitted |
30 May 2003 |
|