How do I process a CT/LW set that is missing its assign file (.assg)?


Product

  Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 


Symptoms

 

The CEPS JTP cannot process a CT/LW set if the .assg file is missing.


Cause

  Because it’s hidden on the Mac, this file sometimes gets misplaced.

Solution

 

You can reunite orphaned LWs and CTs using PressTouch. It takes a few steps to put it back into “page context� (.p), but the resulting page works through the CEPS JTP.

The procedure is as follows:

1. Open the LW in PressTouch.

2. In the “CTs� palette, click the new button (bottom of palette). Add the desired CT.

3. The new CT will have a color of “0�. Click the “0�, which brings up a new window.

4. Click the Assign button (pointer becomes an eye dropper). Click to a “gray� part of the LW data that you know the CT is supposed to show through.

5. Save as a Page, then bring the resulting page into Prinergy via the CEPS JTP.

6. Check your output results carefully to ensure that the page is as you expect.

Permanent fix:


See also

 


Keywords

 

CT-LW Import


Technical contact(s)
 

James Bredenhof