Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Render JTP crashes after switching between 3011 and 3016 RIPs


Product

  2.2.1.10

Platform

 

Operating system

 


Error

 


Symptoms

 

Render JTP crashes after switching between the 3011 and 3016 RIPs (3011 to 3016, or 3016 to 3011).

The JTP starts okay, but crashes when first output is attempted.


Cause

  If the new JTP (3016) has the same name as the previous JTP of the other type (3011), then it gets confused by the screen cache that was already built by the previous type of RIP.

Solution

 

1) When switching between RIPs, use a different name so the new type doesn't get confused by the previous type's screen cache, or

2) After upgrading, immediately switch the JTPs (don't run the previous type of JTP), or

3) Manually go in and delete the contents of %ARAXIHOME%\AdobeExtreme\bin\CreoScreens\Cache

.

This is not a problem in Prinergy 2.3.x or 2.2.1.11, where ONLY the 3016 RIP is available.

Permanent fix:


See also

 


Keywords

 

JTP, RIP, output, plate


Technical contact(s)
 

James Bredenhof

Submitted by
 

James Bredenhof

Date submitted
 

24 Sep 2004