Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Although the FPO from Mediabank is present in the PS, Prinergy does not swap in the high rez data. |
|
|
|
||
Cause |
The construction of the MediaBank's OPI form bounding boxes are not quite legal. | |
|
|
||
Solution |
In Prinergy 2.1 patch 17 or higher, activate the following registry key: HKLM\Software\Creo\Araxi\Default\ENOR\NormJTPName\OPIRepairInvalidFormBBox = 1 . This change is manual, (not applied universally to all Prinergy servers) because there is concern that this change may cause problems for other legitimate OPI formats that are already working. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
OPI |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
James Bredenhof |
|
Date submitted |
21 May 2003 |
|