Orbix daemon and Extreme Coordinator fail due to incorrect TCP/IP hosts file entries


Product

  Prinergy 1.1; Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

Errors in the diagnostic log:

- suggest that the Orbix Daemon is not running, when in fact it is.

- indicate that the Device and Services Daemon fails to connect to the Extreme Coordinator.

- Clients connecting to CORBA servers get timeout errors.

See PR details for error messages.


Cause

  Incorrect entries in the TCP/IP hosts file.

The Locator Daemon updates the TCP/IP hosts file on each Prinergy node to improve Orbix performance by making IP address <-> hostname lookup faster.

For example, opening a job window in Workshop can be up to 5 seconds faster with this compared to without.


Solution

 

1. Remove the incorrect IP address entries in the hosts file.

2. Restart Prinergy.

See PR details for more detailed instructions.