Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 2.3, 3.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
None. |
|
|
|
||
Symptoms |
When editing/creating an output process plan, the screening parameters are blank. |
|
|
|
||
Cause |
The screening parameters are stored in a file that gets generated everytime an output JTP is started/re-started. Sometimes, the file is not complete and this results in the drop-down lists in the process plan being blank. | |
|
|
||
Solution |
Re-starting the relevant output JTP (proofing, Print Console, etc.) will cause the parameter file to be re-generated. This usually works the first time but if it doesn't work the first time, then try deleting the contents of the following folder (\CreoAraxi\data\DeviceAndServices\DynamicParameters) and restart Prinergy. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
screening |
|
|
|
||
Technical contact(s) |
James Bredenhof |
|
Submitted by |
James Bredenhof |
|
Date submitted |
03 Aug 2005 |
|