Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Job fails to export


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

Some Prinergy jobs may fail on export. Actually, export fails on one particular page (as usual, the most complicated).

Error in Workshop: Message from Extreme: export-job Failed processing: .. Message from ARAXI log: RAXI PImpExpJTP.main IEXJ_ImportExportJTP.cpp(372): CORBA system exception while processing JT - 10087-- Communication failure - timeout [Completion status : COMPLETED_YES]


Cause

 

Solution

 

Edit the registry settings. Change the value for the registry IEXJ\ImportExportOn\CopySubPageTimeOut from 180000 milliseconds to 240000 or 300000 milliseconds.

Permanent fix:


See also

 


Keywords

 

workshop


Technical contact(s)
 

Gordon Miller