Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Some Prinergy jobs may fail on export. Actually, export fails on one particular page (as usual, the most complicated). Error in Workshop: Message from Extreme: export-job Failed processing: .. Message from ARAXI log: RAXI PImpExpJTP.main IEXJ_ImportExportJTP.cpp(372): CORBA system exception while processing JT - 10087-- Communication failure - timeout [Completion status : COMPLETED_YES] |
|
|
|
||
Cause |
||
|
|
||
Solution |
Edit the registry settings. Change the value for the registry IEXJ\ImportExportOn\CopySubPageTimeOut from 180000 milliseconds to 240000 or 300000 milliseconds. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
workshop |
|
|
|
||
Technical contact(s) |
Gordon Miller |
|
Submitted by |
||
Date submitted |
||