Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
Device link ID unknown (sic) |
|
|
|
||
Symptoms |
Submitting a certified proof to Veris fails. In Prinergy Workshop, the Prinergy Server Diagnostic Log reports the error: Device link ID unknown (sic). Uncalibrated and calibrated proofs work OK. |
|
|
|
||
Cause |
There are two possible causes: 1. Device link profile ID is not exactly the same on Prinergy and Veris. 2. ColorMatch setting is set to Heidelberg instead of Creo. |
|
|
|
||
Solution |
Solution 1: Copy the device link from Veris to Prinergy. Solution 2: Change ColorMatch to ColorMatcherCreo. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
proofing, workshop |
|
|
|
||
Technical contact(s) |
Ken Lew |
|
Submitted by |
Harry Jung |
|
Date submitted |
26 Feb 2004 |
|