Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy reports an internal error when processing a certified proof on Veris


Product

  Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 

Device link ID unknown (sic)


Symptoms

 

Submitting a certified proof to Veris fails. In Prinergy Workshop, the Prinergy Server Diagnostic Log reports the error: Device link ID unknown (sic). Uncalibrated and calibrated proofs work OK.


Cause

  There are two possible causes:

1. Device link profile ID is not exactly the same on Prinergy and Veris.

2. ColorMatch setting is set to Heidelberg instead of Creo.


Solution

 

Solution 1: Copy the device link from Veris to Prinergy.

Solution 2: Change ColorMatch to ColorMatcherCreo.

Permanent fix:


See also

 


Keywords

 

proofing, workshop


Technical contact(s)
 

Ken Lew

Submitted by
 

Harry Jung

Date submitted
 

26 Feb 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.