Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Veritas 2.11 Hotfix 8 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Cannot start Veritas services. Cannot start or complete Prinergy-database job. |
|
|
|
||
Cause |
Possibly a corrupt Veritas database. | |
|
|
||
Solution |
Solution 1: Delete and recreate the prinergy job with the replication script. Create the replication job from the script at: D:\Program Files\VERITAS Storage Replicator\Creo\Prinergy-Database\Create&StartPrinergy-DatabaseJob.cmd Solution 2: 1. Stop all Veritas services, Storage Replicator RMS, and RSA 2. Browse to directory J:\VSR\Databases and rename the files RXDB RXDB.index 3. Start the Storage Replicator RMS and RSA services. This will recreate the Vertias Database without any jobs. 4 Create the replication job from the script at: D:\Program Files\VERITAS Storage Replicator\Creo\Prinergy-Database\Create&StartPrinergy-DatabaseJob.cmd Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
Database Reports, EPM, Emergency Platemaking (EPM), backup |
|
|
|
||
Technical contact(s) |
Philip Samaniego |
|
Submitted by |
Gary Tanaka |
|
Date submitted |
06 Jun 2005 |
|