Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Cannot start Veritas services or cannot start or complete Prinergy-database job


Product

  Veritas 2.11 Hotfix 8

Platform

 

Operating system

 


Error

 


Symptoms

 

Cannot start Veritas services. Cannot start or complete Prinergy-database job.


Cause

  Possibly a corrupt Veritas database.

Solution

 

Solution 1:

Delete and recreate the prinergy job with the replication script. Create the replication job from the script at:

D:\Program Files\VERITAS Storage Replicator\Creo\Prinergy-Database\Create&StartPrinergy-DatabaseJob.cmd

Solution 2:

1. Stop all Veritas services, Storage Replicator RMS, and RSA

2. Browse to directory J:\VSR\Databases and rename the files

RXDB

RXDB.index

3. Start the Storage Replicator RMS and RSA services.

This will recreate the Vertias Database without any jobs.

4 Create the replication job from the script at:

D:\Program Files\VERITAS Storage Replicator\Creo\Prinergy-Database\Create&StartPrinergy-DatabaseJob.cmd

Permanent fix:


See also

 


Keywords

 

Database Reports, EPM, Emergency Platemaking (EPM), backup


Technical contact(s)
 

Philip Samaniego

Submitted by
 

Gary Tanaka

Date submitted
 

06 Jun 2005