Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 1.0; Prinergy 1.1; Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Add a curve using the Harmony application. The curve does not show up in the Prinergy Process Plan Editor |
|
|
|
||
Cause |
Improper Harmony configuration. Prinergy and Harmony are installed using unique installers. After both are installed, there are a few manual steps that must be followed to make Prinergy and Harmony work together (see the installation procedure for details). After you perform the manual configuration, you must restart Prinergy. | |
|
|
||
Solution |
Perform the manual configuration steps as documented in the installation procedure. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
calibration, Harmony, pped |
|
|
|
||
Technical contact(s) |
Rob Prior |
|
Submitted by |
||
Date submitted |
||