Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


How do I get the same angle sets in Prinergy as I previously had with my Allegro/Harlequin RIP?


Product

  Prinergy 1.0; Prinergy 1.1; Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

Customer wants to get "traditional" Allegro angles of CMYK at 15-75-0-45 degrees.


Cause

  The angle definitions provided in the PPED UI are all specified in the clock coordinate space, where 0 degrees is at 12 o'clock and positive angles are clockwise. Harlequin RIPs run with 0 degrees at 3 o'clock and positive angles counterclockwise. The clock coordinate system is common in film workflows and in Delta IS shops.

Solution

 

Get output patch 31 or later.

Select screen system set Creosettes CMYK 75-15-90-45.

Note that the Creosettes family of screen systems has the EllipticalP dot shape running with its long axis along the angle direction, as in the Allegro workflow.

Permanent fix:


See also

 


Keywords

 

Allegro, color, screening


Technical contact(s)
 

Rob Prior