Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy dongle appears to be failing


Product

  Prinergy 1.1; Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

Prinergy dongle appears to be failing.


Cause

 

Solution

 

(1) Re-seat the dongle and ensure the sentinel device driver is running/active in the "Control Panel -> Devices" (probably do a re-boot as well); look in the WinNT Event log for any details of device failure or service failure.

(2) Re-install the sentinel driver.

(3) Look into the dongle diagnostic file in "%ARAXIHOME%\CreoAraxi\License\Licchk.dia" to see if there is any hint as to the cause of the problem.

(4) Check the parallel port HW and configuration.

Since the customer is basically hard down when the dongle has a problem, we should probably dispatch a new dongle ASAP so that we can get the customer up ASAP. It would be bad to troubleshoot for two days and then discover that a faulty dongle was the problem.

Permanent fix:


See also

 


Keywords

 

administrator


Technical contact(s)
 

Simon Chen

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.