Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 1.1; Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Satellite | |
Platform |
Dell or Data General |
|
Operating system |
Windows NT or 2000 |
|
|
|
||
Error |
D:\>ppu Exception in process 221, thread 48 Traceback (innermost last): File "ppu.py", line 190, in run self.getopts() File "ppu.py", line 351, in getopts self.node.Query() File "ppunode.py", line 36, in Query nodeinfo.PrinergyNodeInfo.Query( self ) File "nodeinfo.py", line 107, in Query AraxiHomeShareInfo = MyRegQueryValue( hklm, subkey, 'AraxiHome', win32con.RE G_MULTI_SZ ) File "nodeinfo.py", line 43, in MyRegQueryValue raise KeyError( 'registry value not found' ) KeyError: registry value not found |
|
|
|
||
Symptoms |
The Prinergy Patch Utility (PPU) is a utility that is used to install software updates to the Prinergy system. When attempting to start the PPU, it fails to start and displays an error message indicating that the registry value could not be found. |
|
|
|
||
Cause |
The folder where Prinergy is installed must be shared (NT share) as the "AraxiHome" folder. | |
|
|
||
Solution |
Fix the share of the Prinergy folder. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
ppu |
|
|
|
||
Technical contact(s) |
Stan Yoshida |
|
Submitted by |
Kevin Ishiguro |
|
Date submitted |
13 Sep 2002 |
|