Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy Patch Utility (PPU) fails to startup with a "registry value not found" error


Product

  Prinergy 1.1; Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Satellite

Platform

 

Dell or Data General

Operating system

 

Windows NT or 2000


Error

 

D:\>ppu

Exception in process 221, thread 48

Traceback (innermost last):

File "ppu.py", line 190, in run

self.getopts()

File "ppu.py", line 351, in getopts

self.node.Query()

File "ppunode.py", line 36, in Query

nodeinfo.PrinergyNodeInfo.Query( self )

File "nodeinfo.py", line 107, in Query

AraxiHomeShareInfo = MyRegQueryValue( hklm, subkey, 'AraxiHome', win32con.RE

G_MULTI_SZ )

File "nodeinfo.py", line 43, in MyRegQueryValue

raise KeyError( 'registry value not found' )

KeyError: registry value not found


Symptoms

 

The Prinergy Patch Utility (PPU) is a utility that is used to install software updates to the Prinergy system. When attempting to start the PPU, it fails to start and displays an error message indicating that the registry value could not be found.


Cause

  The folder where Prinergy is installed must be shared (NT share) as the "AraxiHome" folder.


Solution

 

Fix the share of the Prinergy folder.

Permanent fix:


See also

 


Keywords

 

ppu


Technical contact(s)
 

Stan Yoshida

Submitted by
 

Kevin Ishiguro

Date submitted
 

13 Sep 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.