Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Harmony asks for cal sets for screens that shouldn't exist in the job


Product

  Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 

RIP Error: Failed to find automatic Harmony calibration curve matching criteria: Medium = 900 (Kodak IR)


Symptoms

 

Harmony asks for cal sets for screens that shouldn't exist in the job. It seems to find the staccato curve it needs, but then fails asking for dozens of curves it shouldn't need (106 and 100 lpi).


Cause

  The refined .pdf file has a default halftone for one of the Graphics States (the halftone "HT" for graphics state 1 is "Default"). This just means

to use "the halftone that was in effect at the start of the page". In Prinergy, we always set up a default halftone in a startup postscript file. This is never really meant to be used, but we have to set it for some

reason at Extreme startup time (this probably goes away when using the new PJTP, but we'll have to fix this). We set this value to 106 lpi. The 100 lpi is coming from the process plan. I'm not really sure why.

Again, it's probably related to the default halftone again. This time not from the startup .ps, but from the process plan. It's all quite strange, and it think much of it had to do with working around problems with Extreme

(it's all stuff that William setup years ago).


Solution

 

Set up a dummy calibration curve for these rulings.

Permanent fix:


See also

 


Keywords

 

calibration, Harmony, screening


Technical contact(s)
 

Devon McCrea

Submitted by
 

Ken Lew

Date submitted
 

25 August 2003