auto-select mechanism for calibration curvers not working for spot colors


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1

Platform

 

Operating system

 


Error

 

RIP Error: Failed to find automatic Harmony calibration curve matching criteria: Medium = 900 (Kodak IR)...


Symptoms

 

task fails due to not finding a suitable calibration curve


Cause

  Although Harmony doesn't need it, Prinergy needs a spot color to have a screen angle assigned otherwise the auto function will not work.

Solution

 

There are 3 workarounds:

1. specify the spot color and an angle in the output process plan under "Cailbration and Screening" tab.

2. specify a screen angle in the Global Color Editor for the spot color.

3. specify a screen angle in the Per-jobl Color Editor for the spot color.

Note: for any of this to work, there must also be a Harmony curve defined in the Harmony database for the spot color.

Permanent fix:


See also

 


Keywords

 

color, dot-gain calibration, Harmony, spot color