Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
None. |
|
|
|
||
Symptoms |
A crosshatch pattern may be visible on some separations, depending on the screen angle, spot function, and tint value. |
|
|
|
||
Cause |
||
|
|
||
Solution |
In Prinergy 2.1 and later, the workaround is: 1. Select 138 lpi (by typing it in) instead of 150 lpi. 2. Select a Round-Square (Euclidean) dot rather than a Round dot. . The difference in actual ruling on the plate is negligible, because 150 lpi actual results in screens that are about 141 lpi. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
output, RIP, screening |
|
|
|
||
Technical contact(s) |
Ken Lew |
|
Submitted by |
Ken Lew |
|
Date submitted |
19 Jan 2004 |
|