"Reload the Automation Proxy" error message in Prinergy Workshop


Product

  Prinergy 3.0, Prinergy 3.1

Platform

 

Operating system

 


Error

 

"Reload the Automation Proxy" will show up in Workshop under the Tools menu instead of "Rule Set Manager".


Symptoms

 

"Reload the Automation Proxy" error message in Prinergy Workshop


Cause

  This error message occurs when the client (Prinergy Workshop) cannot connect to the Automation engine on the server. There could be several reasons why this may happen.

Solution

 

Things to check for:

1. Is WebServerApp.exe running on the server?

2. Is AutomationApp.exe running on the server?

3. Is there a version mismatch between Workshop and the server? This will result in a non-intuitive error: (407)Proxy Authentication Required.

4. Is there a firewall between the Workshop client and the server? If so, make sure that TCP port 61234 and 61235 is open and listening. Try the following commands in a DOS window.

D:\>netstat -a | findstr 6123

The result should be:

TCP ctp:61234 ctp:0 LISTENING

TCP ctp:61235 ctp:0 LISTENING

5. Are they using an HTTP proxy? If so, don't use one and see what happens.

For Mac users only:

1. Try adding the IP address of the Prinergy server into the "'Bypass proxy settings for these hosts & domains" list in Mac OS X and restart the Mac.

2. Run MacOS Disk Utility (Applications -> Utilities folder) and click "Repair disk permissions".

Permanent fix:


See also

 


Keywords

 

Automation, workshop


Technical contact(s)
 

Ken Boyle

Submitted by
 

Ken Lew

Date submitted
 

16 Dec 2005