Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
In an output processing plan, you can't see screening parameters when the render JTP selected is a proofing pool. |
|
|
|
||
Cause |
The registry problem that causes the missing screening info is that the list of JTPs in a pool in the following registry key: DASS\Services\<POOLNAME>\PoolServices does not match the actual list of JTPs in the pool. |
|
|
|
||
Solution |
There are two ways to fix the problem: Method 1: Fix the registry: - Go into the registry and make sure the list of JTPs in the pool -- registry key DASS\Services\<POOLNAME>\PoolServices matches the actual JTPs in the pool. Method 2: - Change process plan to refer to a JTP rather than a pool. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
pped, process plans |
|
|
|
||
Technical contact(s) |
Simon Chen |
|
Submitted by |
||