Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Measurement unit for variable marks is always in points on imposed output


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

The customer want to use inches as the unit of measurement for variable marks on imposed output, but can only get points.


Cause

  Settings in the process plan determine the unit of measurement used by the Marks JTP. For a loose page proof, the measurement unit should be set in the process plan. The very last line of the layout section has an option For Variable Marks. Unfortunately, this is not available as an option for imposed proofs. For the Marks JTP, the default setting is in points. The Marks JTP supposedly wipes out all settings in the Preps JT. The Workshop settings have no effect as they are only for the GUI.

Solution

 

There is no workaround at this time. The problem must be fixed by Heidelberg, as they control the Process Plan Editor.

Permanent fix:


See also

 


Keywords

 

output, variable marks


Technical contact(s)
 

Louise McTague

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.