Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


CEPS JTP cannot process CEPS page without an "assign" or "final page" file


Product

  Prinergy Connect 2.0 ; Prinergy Connect 2.1

Platform

 

Operating system

 


Error

 


Symptoms

 

CT/LW: CEPS page does not show up in the "Input Files" section of the Workshop.

TIFF/IT: CT and LW both show up as 2 input files in the "Input Files" section of the Workshop, and then fail to Refine.


Cause

  The CEPS JTP cannot process "orphaned" CT, LW, and HC files. It requires the FP (final page) file (if page is TIFF/IT) or the .assg (assign) file (if page is CT/LW).


Solution

 

Obtain the required FP or .assg file and process the file.

.

Note 1: When submitting a CEPS page to Prinergy, you only have to "Add" the FP or .assg file. Since the FP or .assg file is the master file (it has internal references to the LW and CT files), Prinergy will automatically pick up the required pieces.

.

Note 2: The .assg file is hidden from the Macintosh. Consult the "Best Practices for Creating CT/LW for Input into Prinergy" document for tips on obtaining this file.

Permanent fix:


See also

 


Keywords

 

CT-LW Import


Technical contact(s)
 

James Bredenhof