Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


(2.0) Retrieve fails with Error 13: “Win32 message = The data is invalid�


Product

  Prinergy Connect 2.0

Platform

 

Intel

Operating system

 

Windows 2000 Server


Error

 


Symptoms

 

Retrieve fails with the following error:

d 26Apr01 13:15:25.859-PDT [4152.4828] GATOR AraxiLab PArchRetJTP.Medium Retrieve Thread: 4828 SEQM_Araxi10TapeFormat.cpp(1291): File header is correct, source location: \\GATOR\AraxiVolume_GATOR_J\Jobs\New Mexico\VPS-Sigs\New M.Form04_NM_8.1A.1.K.VPS

E 26Apr01 13:15:26.765-PDT [4152.4828] GATOR AraxiLab PArchRetJTP.Medium Retrieve Thread: 4828 SEQM_Araxi10TapeFormat.cpp(1413): SEQM_BackupWrite.Write() failed for file '\\GATOR\AraxiVolume_GATOR_J\Jobs\New Mexico\VPS-Sigs\New M.Form04_NM_8.1A.1.K.VPS'. Error: 13 Win32 message = The data is invalid.


Cause

  When archiving files to two pools, one set of files did not get archived with the complete stream of data; part of it was missing.

Solution

 

Upgrade to 2.0.7

Permanent fix: Prinergy 2.0


See also

 


Keywords

 

archiver - retrieve


Technical contact(s)
 

Amy Chan

Submitted by
 

Amy Chan

Date submitted
 