Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 3.1.0.3 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Values entered for the following keys must be swapped for correct detection during preflight PDF Version key is not set to... (PDFXVersion) Trapnet Annotation does not conform to... (PDFXVersionForTrapNet) |
|
|
|
||
Cause |
UI bug in Prinergy 3.1.0.3 | |
|
|
||
Solution |
Workaround for the user: when modifying the Advanced Preflight Profile, swap values in the input fields entered for PDFXVersion and PDFXVersionForTrapNet. Screenshot of selections attached for reference Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
workshop |
|
|
|
||
Technical contact(s) |
||
Submitted by |
Malcolm Kenning |
|
Date submitted |
06/10/2006 |
|