When you try to create a replication set using the CreateRepset.cmd or DT_Configure.cmd scripts, the error "insufficient access level" is displayed. |
|
|
|
||
Symptoms |
Failure to create replication set. When you try connecting to a server in the DoubleTake Management Console, double-clicking the server launches a login dialog box. Using the current login fails. |
|
|
|
||
Cause |
Double-Take administrators should be a member of the "Double-Take Admin" Group. When Double-Take is installed, the Double-Take Admin group is populated with all the users in the Administrators group. Users with administrator privileges that are added after the Double-Take installation will not be in the Double-Take Admin group. | |
|
|
||
Solution |
Add all new user acounts which will be used to configure Double-Take to the Double-Take Admin group. Permanent fix: |
|
|
|
||