Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Hot Standby with VSR Prinergy-Database replication job disappears


Product

  Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 ; Prinergy Powerpack 2.1 ; Prinergy 2.3, 3.0, 3.1

Platform

 

Operating system

 

Windows 2000, SP4


Error

 

A pop-up window appears on the Prinergy servers reporting that the Prinergy-Database replication job is not running.


Symptoms

 

After you restart the primary, the Prinergy-Database replication job disappears.


Cause

  The VSR database may be corrupt.

Solution

 

Create new VSR database files.

1. On the Prinergy primary server, stop the RMS service.

2. Locate the VSR database directory (<DataDrive>:\VSR\Databases).

3. Rename the RXDB and RXDB.index files.

4. Restart the RMS service. This will create new database files.

5. Open the VSR console.

6. Recreate the Prinergy-Database replication job by running the Create&StrtPrinergy-DatabaseJob.cmd script.

7. Monitor the system if the replication job remains intact after restarting the server.

Permanent fix:


See also

 

http://support.veritas.com/docs/245296


Keywords

 

EPM, Emergency Platemaking (EPM), Hot Standby, administrator, backup


Technical contact(s)
 

Philip Samaniego

Submitted by
 

Philip Samaniego

Date submitted
 

09 Nov 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.