DoubleTake encounters an Event 8196 (logged in Event Viewer) and triggers a re-mirror


Product

  Prinergy 3.x, 4.x

Platform

 

Operating system

 

Windows 2000/2003 server


Error

 

System Event Log:

Event Type: Warning

Event Source: Dblhook

Event Category: Resources

Event ID: 8196

Date: 10/6/2006

Time: 6:44:49 AM

User: N/A

Computer: P3LAB2600

Description:

The maximum amount of memory for replication queuing has been reached. Replication is stopped and memory is being freed.

Data:

0000: 00 00 04 00 01 00 5c 00 ......\.

0008: 02 00 00 00 04 20 f1 8f ..... ñ�

0010: b3 14 34 93 00 00 00 00 ³.4?....

0018: 00 00 00 00 00 00 00 00 ........

0020: 00 00 00 00 00 00 00 00 ........

0028: 90 ec 00 08 �ì..


Symptoms

 

Dblhook logs an Event 8196 to the System Event Log. Replication is stopped and a remirror is triggered. If e-mail notification is enabled, an e-mail with the following message is sent:

Description: The maximum amount of memory for replication queuing has been reached. Replication is stopped and memory is being freed.

Server: P3LAB2600

Source: Dblhook

Id: 8196

Severity: Warning

Category: Resources

Time: 10/06/2006 06:44:49


Cause

  Event 8196 occurs when the replication queue cannot be flushed fast enough. This may occur when the server is very busy, or the DoubleTake kernel driver being overwhelmed by the amount of data changes in the source folders.

Solution

 

Do the following on the server where the problem is seen.

1. Change the DoubleTake disk queue from the Data drive (usually J:\) to a drive which is not very busy.

2. If using an anti-virus software, exclude DoubleTake.exe and the DoubleTake disk queue from real-time virus scan.

3. If there is available physical memory, increase the DoubleTake memory queue.

4. If error is on a Primary server, exclude *.bck files (in the OracleBackupFolder) in the PrinergyDB replication set. The repset needs to be disconnected and modified. This is done using the DT Management Console. Right-click on the repset and select properties. Use the Rules tab to modify the repset. Save the modified repset.

5. Run dblhook.reg in <\\ccafs6\araxidata\PR Data\PSamaniego\PSAO-158> to apply settings to the registry.

6. Reboot the server.

Permanent fix:


See also

 


Keywords

 

EPM, administrator, backup


Technical contact(s)
 

Philip Samaniego

Submitted by
 

Philip Samaniego

Date submitted
 

30 Nov 2006