Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Tape Library connected to a PE29x0 does not show up in RSM after reboot


Product

  Prinergy 3.x

Platform

 

DELL PE2900 and PE2950

Operating system

 

W2K Server SP4


Error

 


Symptoms

 

When the server is rebooted, RSM will not be able to detect the tape library. The tape library will have a Red "X" in Removable Storage\Physical Locations and the internal drives will show up as standalone drives. A restart (or several restarts) of RSM would allow it to successfully detect the library. The tape library will work fine after redetection, until the next reboot, when it will not show up again in RSM.


Cause

  There is an interop problem with DELL OMSA v5.1 in PE2900/PE2950, RSM and Qualstar and ADIC FastStor libraries. DELL is currently investigating the issue.

Solution

 

On the PE2900/PE2950 exhibiting the problem, change the startup type of the service "DSM Shared Services" to manual.

Permanent fix:


See also

 


Keywords

 

administrator, archiver, archiver - RSM, backup, tape libraries


Technical contact(s)
 

Philip Samaniego

Submitted by
 

Philip Samaniego

Date submitted
 

20 Sep 2006


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.