HotStandby with DT Replication Monitor generates a false warning


Product

  Prinergy 3.x, 4.x

Platform

 

Operating system

 

Windows 2000, 2003 Server


Error

 

ALERT! The status of the PrinergyDB replication job is: Not connected. . Please see the DT Management Console on SPC_PRINERGY-P for further details. Once fixed, open Replication Monitor window in SPC_PRINERGY-P and hit any key to restart monitoring.


Symptoms

 

Pop-up alerts appear on the desktops of the servers participating in the replication. But the DoubleTake Management Console does not show any problem with the replication job.


Cause

  Replication monitor uses a doubletake command line query to check the status of the replication transmission. If the computer name that is passed on to the doubletake command has a trailing space, the transmission state is sometimes reported as "Not connected".

Solution

 

1. Remove the trailing space from the following lines in the file %ProgramFiles%\DoubleTake\Creo\MonitorDT.cmd. This file can be found in the server where the alerts are originating from (either the primary or the main tertiary server)

set FailoverServer=<FailoverServerName>

set reptype=<PrinergyDB or PrinergyJobs>

2. On the Primary and the main tertiary server, replace %ProgramFiles%\DoubleTake\Creo\MonitorSetup.cmd with the one in \\ccafs6\araxidata\PR Data\PSamaniego\PSAO-173.

This problem is fixed in the RevG of the HotStandby with DT installer (651-00325A-G).

Permanent fix:


See also

 


Keywords

 

EPM, administrator


Technical contact(s)
 

Philip Samaniego

Submitted by
 

Philip Samaniego

Date submitted
 

07 Jun 2007