Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


(2.0) "Unable to complete medium" error logged to DIAG log by Prinergy 2.0.7 Archiver


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 

E 28Aug01 15:00:36.640-PDT [5904.108144] YCS175-83 ARAXI PArchRetJTP.Medium Retrieve Thread: 108144 NTMS_RemovableMedium.cpp(897): unable to complete medium. Status = 5023Medium ID = a4264bbd-deec-4480-aa7a-ef2f76118ee7 Medium name = 000042 NTMS logical medium ID = cb7b36dc-08b7-4260-b1d3-bd8922019bb4


Symptoms

 

"Unable to complete medium" error logged to DIAG log by Prinergy 2.0.7 Archiver.

No other symptoms or indications of a problem appear.


Cause

  The Windows 2000 RSM allows an application to "complete" a medium as a way of marking it as "full" or 'read-only". We added some code to do this, but overlooked that the medium has to be "idle" to be completed.

Solution

 

Ignore the error message. This will be fixed in Prinergy 2.1, and does not impact other functionality in any way.

Permanent fix:


See also

 


Keywords

 

archiver


Technical contact(s)
 

Amy Chan

Submitted by
 

Rob Dal-Santo

Date submitted
 

29 Aug 2001


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.