Trapped Prinergy PDFs look wrong when output on 3rd party RIPs |
|
|
|
||
Cause |
There can be a number of possible causes. Most likely is that the 3rd party RIP does not support Postscript 3 objects or Overprints. The traps created by Prinergy contain overprinting objects and in many cases are defined in DeviceN color space. | |
|
|
||
Solution |
Try a vector output type like DCS or PS level 2 that is pre-separated. See the page in Tech planet fora test page and a list of supported devices at: http://techplanet.creo.com/software_solutions/workflow_software/prinergy/content/docs/vector_output/index.htm Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
Imagesetter, trapping, vector output |
|
|
|
||