Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Trapping fails on files with blends and reports PDF Library Error or blend color space error message


Product

  Prinergy Connect 2.1 Level 2.2.1.8; Prinergy Direct 2.1 Level 2.2.1.8; Prinergy Access 2.1 Level 2.2.1.8; Prinergy Powerpack 2.1 Level 2.2.1.8

Platform

 

Any

Operating system

 

Any


Error

 

"PDF Library Error: Expected an array object"

or

"Unsupported blend color space separation"


Symptoms

 

Certain files containing blends may fail in the Trapping JTP on systems running Prinergy 2.2.1.8 up to 2.2.1.11


Cause

  A problem in the trapper's blend detector causes a crash when trapping files containing blends.

Solution

 

This problem will be fixed in Prinergy 2.2.1.12 and 2.3.1.2.

Upgrade to Prinergy 2.2.1.12 or 2.3.1.2

Permanent fix:


See also

 


Keywords

 

trapping


Technical contact(s)
 

Rob Morgan

Submitted by
 

Rob Morgan

Date submitted
 

10 Sep 2004


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.