Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 ; Prinergy Connect 2.1 ; Prinergy Direct 2.1 ; Prinergy Access 2.1 | |
Platform |
||
Operating system |
||
|
|
||
Error |
%%[ Error: limitcheck; OffendingCommand: imagemask ]%% |
|
|
|
||
Symptoms |
The Temporary drive (E:\Temp) fills up during rendering of a job that contains copydot images. PostScript error, Limitcheck: Imagemask, occurs during rendering of a job that contains copydot images, and the output JTP disconnects. |
|
|
|
||
Cause |
One possible cause is that the copydot images may have not been tiled in the most efficent way. For best performance, copydot images should be formatted in 2048 x 2048 tiles. | |
|
|
||
Solution |
Re-refine the PDF pages with the Copydot JTP enabled, or use Copydot Toolkit to re-format the images into 2048 x 2048 pixel tiles. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
Copydot, PostScript, output |
|
|
|
||
Technical contact(s) |
Rob Morgan |
|
Submitted by |
Rob Morgan |
|
Date submitted |
05 Nov 2004 |
|