Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Unable to connect to the DASS Daemon


Product

  Prinergy 1.1

Platform

 

Operating system

 


Error

 


Symptoms

 

Unable to connect to the DASS Daemon on SVOZEK_7000 (10241 -- Invalid operation - The server '{no value available}' is not registered in the implementation repository. [ Use the 'putit' command to register a new server]


Cause

  Prinergy does NOT run on multi-homed systems if more than one network card is configured to use TCP/IP.

Solution

 

Disable the adapter in the network control panel, or disable TCP/IP in the bindings tab.

Permanent fix:


See also

 


Keywords

 

DASS, networking, orbix


Technical contact(s)
 

Simon Chen

Submitted by
 

Date submitted
 


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.