Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
1) File fails to RIP because it was not able to read Harmony curves. 2) Harmony curve is not available in PPED. 3) Diag reports: suprarip SCRN_Diag.cpp(140): Unable to open Harmony database [e:\Temp\TrendsetterOnCW152v2_TempDirRIP\Calcurve.hmy] No calibration will be active. Reason: Invalid license (15). 4) Prinergy Administrator on secondary servers reports errors binding to DASS, and no JTPs are listed. |
|
|
|
||
Cause |
When the modem is connected to the primary server and someone is dialed in, it causes an intermittent CORBA bind error because the system is multi-homed (2 IP addresses). In Windows 2000, the address for the RAS connection does not get released until you reboot. | |
|
|
||
Solution |
1) Rebooting the primary server will release the IP address assigned for RAS. 2) Move the modem to a secondary server. Permanent fix: Prinergy 2.0 |
|
|
|
||
See also |
||
|
|
||
Keywords |
administrator, Harmony, RIP |
|
|
|
||
Technical contact(s) |
Simon Chen |
|
Submitted by |
||
Date submitted |
||