Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy Connect 2.0 | |
Platform |
||
Operating system |
||
|
|
||
Error |
||
|
|
||
Symptoms |
Importing the imposition fails with the following error: PImpExpJTP.main IEXJ_ExtractProcessingContext.cpp(181): No OrigImportFilePath detected. ImportExport: Failed to copy the file \\PASSAT\AraxiVolume_PASSAT_G\Test to the temp folder \\PASSAT\AraxiTemp_PASSAT_E\Temp\ImportExportOnPASSAT\APAThumbtest_import_9d0d6ada84a7304bbf7637a68eddbad1. ImportExportOnPASSAT:import-firstpass: Message from Extreme: ImportExportOnPASSAT:import-firstpass Failed processing: .. X 02Mar01 03:35:01.640 [3092.3132] PASSAT ARAXI PTaskD.XCON_Callback TAKS_JobSub.cpp(1232): Test\TaylorNew.JT: processing has completed. |
|
|
|
||
Cause |
After the Job Ticket (JT) has been created, the files cannot be renamed. Even if you rename the JT and the PS file with the same base name, the JT will not be able to find the PS file because the JT references the PS marks file internally. | |
|
|
||
Solution |
Rename the files with the original name. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
imposition [layout], job ticket |
|
|
|
||
Technical contact(s) |
Louise McTague |
|
Submitted by |
||
Date submitted |
||