CIP3 preview files are left on the system disk


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 


Symptoms

 

CIP3 preview files are left in the AraxiHome\CreoAraxi\data\CIP3-Preview Files folder.


Cause

  In certain cases where plates are cancelled, CIP3 preview files are left in the system drive. This has been fixed and will be in the next release, 2.0.7. The normal behavior will be that Prinergy will try to connect to the FTP server 3 times per file. If it fails, it will automatically delete the files. In addition, the files will also be compressed so that they will take up less room.

Solution

 

Ensure “delete file after FTP completes� is enabled in the output process plan.

Delete the old files.

Permanent fix: Prinergy 2.0