Error |
Under History: "The workflow terminated without processing any files." |
|
|
|
||
Symptoms |
Files added via a hot folder do not show up in Workshop under Input Files. There are no files in the Rejected folder. |
|
|
|
||
Cause |
The file must be registered into the system before a process task can be created. The system failed to register the file because it was either corrupt or an unsupported format. | |
|
|
||
Solution |
Correct the problem with the input file and add the file to the job again. Permanent fix: |
|
|
|
||
See also |
||
|
|
||