Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Jobs previously PostScript bypassed fail to output after installing 2.0.7.11


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 

X 13Dec01 22:52:46.109 [2812.2980] WILMA ARAXI PTaskD.XCON_Callback TAKS_JobSub.cpp(1370): ProofonWilma:printing: Message from Extreme: message from RIP: %%[ Error: typecheck; OffendingCommand: not ]%


Symptoms

 

Job that were previously bypassed fail to output after installing 2.0.7.11


Cause

  The bypass mechanism has changed in order to support OPI bypass, an upcoming feature.

Solution

 

The workaround is to simply re-refine the files. Since the files are bypassed they should not take long to re-refine.

This problem is fixed in 2.0.7.14

Permanent fix: Prinergy 2.0


See also

 


Keywords

 

output, refiner


Technical contact(s)
 

Simon Chen

Submitted by
 

Simon Chen

Date submitted
 

20 Dec 2001


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.