Error |
X 13Dec01 22:52:46.109 [2812.2980] WILMA ARAXI PTaskD.XCON_Callback TAKS_JobSub.cpp(1370): ProofonWilma:printing: Message from Extreme: message from RIP: %%[ Error: typecheck; OffendingCommand: not ]% |
|
|
|
||
Symptoms |
Job that were previously bypassed fail to output after installing 2.0.7.11 |
|
|
|
||
Cause |
The bypass mechanism has changed in order to support OPI bypass, an upcoming feature. | |
|
|
||
Solution |
The workaround is to simply re-refine the files. Since the files are bypassed they should not take long to re-refine. This problem is fixed in 2.0.7.14
Permanent fix: Prinergy 2.0 |
|
|
|
||