Illegal characters in job name causes export to fail


Product

  Prinergy Connect 2.0

Platform

 

Operating system

 


Error

 

E 26Dec01 09:28:04.500-PST [4552.2492] YCS668-137 ARAXI PImpExpJTP IEXJ_ImportExportJTP.cpp(593): Caught an unexpected exception in ImportExportJTP.

E 26Dec01 09:28:04.500-PST [4552.2492] YCS668-137 ARAXI PImpExpJTP XJTP_Application.cpp(1047): caught Rogue Wave exception while executing task 124: [NPOSINDEX] The value RW_NPOS cannot be used as an index.


Symptoms

 

The Job fails to export and crashes import/export JTP


Cause

 

Solution

 

Rename the Job so it does not contain illegal characters or "-" because this is used in multi-part job exports and will conflict with the naming convention.

Permanent fix:


See also

 