Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Output to directly connected Epson fails with Prinergy 2.0.7.13


Product

  Prinergy Connect 2.0

Platform

 

Server: Dell all; Client: PC or Macintosh

Operating system

 

Server: Windows 2000; Client: Windows or Macintosh


Error

 

The following error is reported in Workshop:

Message from Extreme: JTP used by an active process has disconnected from the coordinator: ColorMatchJTPOnAudi:ColorMatch.[1080072]

The following error is reported in Diag:

E 28Dec01 16:34:42.187-PST [4112.3368] YCS1032-450 ARAXI PColorJTP XTRM_Signature.cpp(232): : precondition failed: (iIndex < GetNumSheets()) at line 232 in file XTRM_Signature.cpp


Symptoms

 

***Applies to Prinergy Connect, Powerpack, Direct, Satellite, depending on installed configuration.***

Imposed output using Epson 5000/9000 causes ColorMatch JTP to fail.


Cause

  Prinergy update 2.0.7.13 introduced a problem with direct Epson output.

Solution

 

Install Prinergy update 2.0.7.14. To update a Prinergy system, Request Support Online.

Permanent fix: Prinergy 2.0


See also

 


Keywords

 

output


Technical contact(s)
 

Simon Chen

Submitted by
 

Simon Chen

Date submitted
 

08 Jan 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.