Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


After dialing into the primary server, CORBA clients on the secondary servers cannot connect to objects on the primary


Product

  Prinergy 1.1; Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Satellite

Platform

 

Dell or Data General

Operating system

 

Windows 2000


Error

 

Internal software error: E 06Jan02 05:14:25.000 [2196.2220] YCS911-417 Administrator uadm.main CORB_ObjRefFactoryImpl.cpp(435): Caught system exception 10241 attempting to bind to :DeviceAndServiceServer on host 10.107.0.144

The IP address in the error message is the one assigned to the WAN.


Symptoms

 

After dialing into the primary server, CORBA clients on the secondary servers cannot connect to objects on the primary.


Cause

  Orbix is using the wrong IP address to connect.

Solution

 

Reboot the primary server to remove the second IP address.

Permanent fix:


See also

 


Keywords

 

networking, orbix, RAS


Technical contact(s)
 

Simon Chen

Submitted by
 

Shelley Hendricks

Date submitted
 

21 Feb 2002


    Copyright © 2005 Creo Inc. All rights reserved. Confidential. Back to top.