Home | Contact Us | Submit Troubleshooting Info | Search | Help
Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS
|
|
||
Product |
Prinergy 1.1; Prinergy Connect 2.0 ; Prinergy Direct 2.0 ; Prinergy Access 2.0 ; Prinergy PowerPack 1.0 ; Prinergy Satellite | |
Platform |
Dell or Data General |
|
Operating system |
Windows 2000 |
|
|
|
||
Error |
Internal software error: E 06Jan02 05:14:25.000 [2196.2220] YCS911-417 Administrator uadm.main CORB_ObjRefFactoryImpl.cpp(435): Caught system exception 10241 attempting to bind to :DeviceAndServiceServer on host 10.107.0.144 The IP address in the error message is the one assigned to the WAN. |
|
|
|
||
Symptoms |
After dialing into the primary server, CORBA clients on the secondary servers cannot connect to objects on the primary. |
|
|
|
||
Cause |
Orbix is using the wrong IP address to connect. | |
|
|
||
Solution |
Reboot the primary server to remove the second IP address. Permanent fix: |
|
|
|
||
See also |
||
|
|
||
Keywords |
networking, orbix, RAS |
|
|
|
||
Technical contact(s) |
Simon Chen |
|
Submitted by |
Shelley Hendricks |
|
Date submitted |
21 Feb 2002 |
|