Error |
Prinergy Diagnostics reports the following error: Could not create/open \\\\<ServerName>\\AraxiHome\\AdobeExtreme\\bin\\<JTPName>_ec_type3 JTP configuration file |
|
|
|
||
Symptoms |
Output JTPs fail to start. Prinergy Administrator reports "error" in the JTP status column. |
|
|
|
||
Cause |
Prinergy folder permissions have been modified. Prinergy requires read and write access so it can log status and write configuration information. | |
|
|
||
Solution |
Check the Prinergy Directory to ensure that everyone has full control and that permissions are not set to read only status. Permanent fix: |
|
|
|
||