Home | Contact Us | Submit Troubleshooting Info | Search | Help


    Output | Software Solutions | Proofing | Color, Screening and Calibration | Scanning | Digital Photography | Consumables | POS


Prinergy Output JTPs fail to start and "error" shows in the JTP status column


Product

  Prinergy Connect 2.0

Platform

 

ALL

Operating system

 

Windows 2000


Error

 

Prinergy Diagnostics reports the following error:

Could not create/open \\\\<ServerName>\\AraxiHome\\AdobeExtreme\\bin\\<JTPName>_ec_type3 JTP configuration file


Symptoms

 

Output JTPs fail to start. Prinergy Administrator reports "error" in the JTP status column.


Cause

  Prinergy folder permissions have been modified. Prinergy requires read and write access so it can log status and write configuration information.

Solution

 

Check the Prinergy Directory to ensure that everyone has full control and that permissions are not set to read only status.

Permanent fix:


See also

 


Keywords

 

JTP, output


Technical contact(s)
 

Simon Chen

Submitted by
 

Simon Chen

Date submitted
 

7 Mar 2002